Description: Schluter Ditra-Heat Cable 120V - 141.1 ft. (42.7 Sq. Ft) DITRA-HEAT is the only system that provides floor warming and uncoupling in a single layer. The heating cables are easily snapped into place on top of the uncoupling mat with no clips or fasteners. The installer has complete flexibility on where the cables are placed so every installation is customized to suit the exact requirements of the owner. Because they are held securely within the DITRA-HEAT mat, there is no need to use self-leveling compounds to encapsulate the heating cables. Instead of waiting for a leveling compound to set, tile installation can begin immediately, resulting in a much faster installation. Features Twisted pair heating cables designed for integration with the DITRA-HEAT membrane Designed for interior floor warming applications Produces virtually zero electromagnetic fields Each heating cable includes 1 floor temperature sensor compatible with the Schluter®-DITRA-HEAT-E-RS thermostat and features an approximately 7 ft (2.1 m) long cold lead Heating Cable selection Tips Do not purchase a heating cable that is the same size as the area to be tiled; you will be left with too much heating cable! Very important: Never CUT or modify the heating cable in any way. This would change the cable resistance, will cause damage to the cable, and could cause cable overheating. Install the heating cable at a spacing of 3 studs (3-1/2" - 9 cm).A narrower spacing may cause a fire or damage the floor covering. A wider spacing (e.g., 4 studs) may not provide sufficient power to warm the floor to the desired temperature. Minimum spacing from other heat sources (baseboard heaters, fireplaces, forced air heating ducts, etc.) is 8" (200 mm) Minimum spacing from any plumbing drain is 6" (150 mm). Minimum spacing from walls is 3" (75 mm). Minimum spacing from fixed cabinets is 2" (50 mm). NEVER install heating cable under vanities, bathtub platforms, kitchen cabinets and islands or any other fixtures. Excessive heat could build up in these confined spaces and may cause a fire. NEVER install the factory splice (i.e., black plastic junction between the cold lead and gray heating cable) in the wall. This will cause overheating, system failure, and could cause a fire. This splice must be installed entirely under the floor covering, as shown in the heating cable installation instructions. It is helpful to plan the location of a buffer zone, as it is not always possible to predict where the heating cable will end. The buffer zone is an area where heating is not essential, typically behind a toilet or adjacent to a door opening. This area allows for placement of excess heating cable. Heating cables may also be installed 6" (150 mm) from the wall to create a buffer zone Consult a qualified electrician before ordering DITRA-HEAT heating cables to ensure you order the correct voltage for your installation. Coverage 141.1 ft. (42.7 Sq. Ft) Manufacturer Part # (MPN) DHEHK12043 Payments Shipping Returns
Price: 254.37 USD
Location: North Hollywood, California
End Time: 2023-11-06T19:12:30.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Return policy details:
Heating System Part: Heating Cable
MPN: DHEHK12043
Brand: Schlüter
Voltage: 120 V