Description: Description: This 10 inch Multi-parameter Monitor is a must-have for ICU, CCU, dental offices, and healthcare facilities. This advanced patient monitor is capable of monitoring signs such as ECG, NIBP, RESP, TEMP, SPO2, and PR. With a large screen display, healthcare professionals can easily track and analyze patient data in real-time. Ensure accurate and reliable patient monitoring with this versatile Signs Machine. Perfect for ensuring patient safety and providing quality care. Packing List: 1×Dental Patient Monitor 1×EKG Lead wire 1×NIBP Cuff 1×NIBP Extension Cable 1×SpO2 Sensor 1×Temp Sensor 3×Limp Clip 5×Electrode 1×User Manual Portable Dental Oral implant?Patient Monitor is adaptable to adult, pediatric and neonatal usage.It?can be used in oral implant surgery. It can monitor and measure human body's signs in real time for patients, especially patients with cardiovascular and cerebrovascular diseases and diabetes, and monitor the changes of life signs in real time, and provide basis for oral implant. Features: 10 inch color high resolution TFT display. Can be arbitrarily set the alarm limit, automatic sound and light alarm Anti-movement, anti-defibrillation, anti electrosurgical interference Remote central monitoring network interface Drug solubility calculation function, Arrhythmia analysis function Built-in lithium battery, AC and DC, can provide long-term monitoring after power failure Widely used in the Department of internal medicine, Dental practices (both pediatric and adult), oral surgery centers surgery, operation room,obstetrics and Gynecology, pediatrics, emergency center, ICU, CCU.?? Standard configuration: ECG, NIBP, SPO2, TEMP, RESP,PR Specification: ECG Lead Mode:5 Leads (?R, L, F, N, C or RA, LA, LL, RL,V) Lead selection:I, II, III, avR, avL, avF, V, Waveform:2 ch Lead mode:3 Leads ( R, L, F or RA, LA, LL) Lead selection:I, II, III, Waveform:1 ch Gain:′2.5mm/mV,?′5.0mm/mV,?′10mm/mV,?′20mm/mV, auto Alarm? Range:? Adult:15 ~ 300 bpm Neo/Ped:15 ~ 350 bpm Accuracy:± 1% or ± 1bpm,which great Resolution:1 bpm Sensitivity:> 200 (uV P-P) Differential Input Impedance:> 5 MΩ RESPARATION: Method:Impedance between R-F(RA-LL) Differential Input Impedance:>2.5 MΩ Measuring Impedance Range:0.3~5.0Ω Base line Impedance Range:0 – 2.5 ?KΩ Bandwidth:0.3 ~ 2.5 Hz Resp. Rate Measuring and Alarm Range? Adult:0 ~ 120 rpm Neo/Ped:0 ~ 150 rpm Resolution:1 rpm Accuracy:±2 rpm Apean Alarm:10 ~ 40 S NIBP Method:Oscillometric Mode:Manual, Auto, STAT Measuring Interval in AUTO Mode ?1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min) Measuring Period in STAT Mode:5 Min Pulse Rate Range:40 ~ 240 bpm Alarm Type:SYS, DIA, MEAN Measuring and alarm range:??? Adult Mode SYS?:40 ~ 270 mmHg DIA?:10 ~ 215 mmHg MEAN:20 ~ 235 mmHg Pediatric Mode SYS:40 ~ 200 mmHg DIA:10 ~ 150 mmHg MEAN:20 ~ 165 mmHg Neonatal Mode SYS:40 ~ 135 mmHg DIA:10 ~ 100 mmHg MEAN:20 ~ 110 mmHg Overpressure Protection Adult Mode:297±3 mmHg Pediatric Mode:240±3 mmHg Neonatal Mode:147±3 mmHg SpO2 Measuring Range:0 ~ 100 % Alarm Range:0 ~ 100 % Resolution:1 % Accuracy:????? 70% ~ 100% ?±2 % 0% ?~ ?69% ?unspecified Actualization interval:about 1 Sec. Alarm Delay:10 Sec. Pulse Rate Measuring and Alarm Range:0~254bpm Resolution:1bpm Accuracy:±2bpm I.5TEMP measurement: Channel:1 Measuring and Alarm Range:0 ~ 50?°C Resolution:0.1°C Accuracy:±0.1°C Actualization interval:about 1 Sec. Average Time Constant: Package List: 1×Dental Patient Monitor 1×EKG Lead wire 1×NIBP Cuff 1×NIBP Extension Cable 1×SpO2 Sensor 1×Temp Sensor 3×Limp Clip 5×Electrode 1×User Manual FDA declaration : Statement:The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item. This item has been cleaned and treated according to the manufacturer's instructions. The Fingertip Pulse Oximeter is certified with the US FDA 510K No. K070371, the CE & TUV of Eureope and it is on the Australian Register of Therapeutic Goods(ARTG) with the code 136606. The Powered Surgical Instrument / Speed 808 System is certified with the US FDA 510(k) Number:K132989 The Powered Surgical Instrument / Hair Remove Device is certified with the US FDA 510(k) Number:K180353 The Powered Surgical Instrument / Hair Remove System is certified with the US FDA 510(k) Number:K141973 massager, vacuum, light induced heating / Slimming Treatment Device is certified with the US FDA 510(k) Number:K161892
Price: 438.99 USD
Location: Chino, California
End Time: 2024-12-12T14:12:11.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: Carejoy
MPN: Does Not Apply