Description: Notifier FDM-1 Module Monitor Dual Addressable w/Flashscan FDM-1 Dual Monitor Module: Enhanced Monitoring Capability The FDM-1 Dual Monitor Module is designed for use in intelligent two-wire systems, offering expanded monitoring capabilities with two independent 2-wire initiating device circuits (IDC) assigned to consecutive addresses. Here are the key details: General Description: Dual Monitoring: Provides two separate, independent 2-wire IDCs, each with its unique address. Versatile Compatibility: Capable of monitoring normally open contact fire alarm and supervisory devices, as well as normally open or normally closed security devices. Specifications: Normal Operating Voltage: Supports a range of 15 to 32 VDC. Maximum Current Draw: Consumes 6.4 mA (LED on). Average Operating Current: Draws 750µA (LED flashing). Maximum SLC Wiring Resistance: Allows up to 40 Ohms. EOL Resistance: Equipped with a 47K Ohms resistor. Maximum IDC Wiring Resistance: Permits up to 1,500 Ohms. Maximum IDC Voltage: Handles a maximum of 11.0 Volts. Maximum IDC Current: Operates with a maximum current of 240 µA. Temperature Range: Suitable for temperatures ranging from 32°F to 120°F (0°C to 49°C). Humidity: Operates efficiently within a humidity range of 10% to 93%, non-condensing. Dimensions: Compact dimensions of 4.675˝ in height × 4.275˝ in width × 1.4˝ in depth, designed to mount to a 4-inch square by 21/8-inch deep box. Accessories: Compatible with SMB500 Electrical Box for installation convenience. The FDM-1 Dual Monitor Module enhances monitoring capabilities within intelligent two-wire systems, offering flexibility and reliability in monitoring a variety of devices. Its dual IDCs, compatibility, and robust specifications make it a valuable addition to such systems. Notifier FDM-1 Module Monitor Dual Addressable w/Flashscan FDM-1 Dual Monitor Module: Enhanced Monitoring Capability The FDM-1 Dual Monitor Module is designed for use in intelligent two-wire systems, offering expanded monitoring capabilities with two independent 2-wire initiating device circuits (IDC) assigned to consecutive addresses. Here are the key details: General Description: Dual Monitoring: Provides two separate, independent 2-wire IDCs, each with its unique address. Versatile Compatibility: Capable of monitoring normally open contact fire alarm and supervisory devices, as well as normally open or normally closed security devices. Specifications: Normal Operating Voltage: Supports a range of 15 to 32 VDC. Maximum Current Draw: Consumes 6.4 mA (LED on). Average Operating Current: Draws 750µA (LED flashing). Maximum SLC Wiring Resistance: Allows up to 40 Ohms. EOL Resistance: Equipped with a 47K Ohms resistor. Maximum IDC Wiring Resistance: Permits up to 1,500 Ohms. Maximum IDC Voltage: Handles a maximum of 11.0 Volts. Maximum IDC Current: Operates with a maximum current of 240 µA. Temperature Range: Suitable for temperatures ranging from 32°F to 120°F (0°C to 49°C). Humidity: Operates efficiently within a humidity range of 10% to 93%, non-condensing. Dimensions: Compact dimensions of 4.675˝ in height × 4.275˝ in width × 1.4˝ in depth, designed to mount to a 4-inch square by 21/8-inch deep box. Accessories: Compatible with SMB500 Electrical Box for installation convenience. The FDM-1 Dual Monitor Module enhances monitoring capabilities within intelligent two-wire systems, offering flexibility and reliability in monitoring a variety of devices. Its dual IDCs, compatibility, and robust specifications make it a valuable addition to such systems. × Buy now and save! Tell a friend Visit store Watch now Postage info Click the Postage tab above the listing description for more info FREE Postage Click the Postage tab above the listing description for more info! Additional delivery notes PICK UP OPTION Sorry, our items are NOT available for pick-up. PAYING VIA PAYPAL We accept PayPal on our all our items so you can shop with confidence. Simple choose the PayPal option when proceeding through the checkout. Additional Information No additional information at this time Ask seller a question You might also like System Sensor 5601P Detector Heat 135 Fixed/ROR Single Circuit System Sensor 4WITAR-B Detector Combo PE/Heat Plug-In 4 Wire 12V/24VDC Silent Knight IDP-RELAY Module Relay Addressable w/2 Isolated Sets Of Gamewell FCI AOM-2RF Module Control Relay Output Addressable Contact To contact our Customer Service Team, simply click the button here and our Customer Service team will be happy to assist. Ask seller a question © ProtegisParts Postage Shipping is FREE for this item Payment Accepted Payment Methods PayPal Returns Returns are accepted Items must be returned within 30 days of the auction ending Buyer will pay for return shipping. eBay integration by
Price: 166.99 USD
Location: Louisville, Kentucky
End Time: 2025-01-23T20:45:25.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: Notifier
MPN: FDM-1