Description: DEF Refractometer - Urea Scales - Urea-Based Diesel Exhaust Fluid (DEF) - MISCO DEF-202 RefractometerThe MISCO DEF-202 digital refractometer is the ideal method for testing and monitoring the concentration of urea-based Diesel Exhaust Fluid (DEF or AdBlue) required by diesel engines equipped with Selective Catalytic Reduction (SCR) technology. This dual scale refractometer has a DEF concentration scale and a refractive index scale.Urea Refractometer for Testing Urea-Based Diesel Exhaust Fluid (DEF / AdBlue) Concentration in Selective Catalytic Reduction (SCR) Equipped Diesel EnginesThe DEF-202 will DEFeat those seeking to DEFraudDiesel Exhaust Fluid (DEF) is already a reality for trucks, buses, and highway vehicles powered by diesel engines. In 2014, new Tier IV guidelines go into effect for off-road equipment as well. These regulations will affect excavators, bulldozers, skid steers and other commercial construction equipment. Also affected are farm tractors and agricultural equipment, heavy forklifts, and airport ground service equipment. Even diesel powered stationary equipment such as generators, pumps, and compressors will be required to meet emission requirements.To comply with EPA regulations, engine manufacturers are using Selective Catalytic Reduction technology which requires a very precise concentration of liquid urea (DEF) in order to operate properly. Selective Catalytic Reduction systems utilize liquid urea, a nitrogen-based compound, to treat diesel exhaust gases prior to them entering a special catalytic converter. The fluid is known as Diesel Exhaust Fluid (DEF) in the US and AdBlue® in Europe. It consists of a very specific concentration of aqueous urea in demineralized water. Injected into the hot exhaust gases as a fine mist, urea turns to ammonia and converts harmful nitrogen oxides (NOx) into harmless nitrogen and water vapor.The best DEFense against diluted DEF.The proper concentration of Diesel Exhaust Fluid (DEF) is crucial to mitigating harmful NOx emissions and prolonging the life of the SCR components. Even concentration variations of as little as +/-0.8% will prevent a DEF fluid from meeting the specifications mandated by International Standards Organization (ISO). DEF dilution or contamination can impact system performance and maintenance costs. The biggest contamination threat is water dilution but without the proper tools it is nearly impossible to know if a DEF supply has been diluted.Get DEFinite results in just seconds.The MISCO Palm Abbe DEF-202 refractometer is the ideal method for testing DEF fluid to ensure it is at the correct concentration and that it has not been diluted or tampered with. It only takes a few drops of DEF and a couple of seconds to perform a test and the results are precise to +/-0.1% urea concentration.Once a few drops of sample have been added to the stainless-steel well, it only takes the press of a single button to initiate a reading. Within seconds, the urea concentration will be displayed on the large 24-character backlit LCD display. The refractometer can also be calibrated to water with the press of a button.Key to the precision and accuracy of the refractometer is the MISCO proprietary OPTICAL-ENGINE®. A combination of high-index sapphire optics and a detector array with 1,024 elements. Special hardware and software automatically temperature compensates readings over a wide temperature range.The DEFinitive choice in DEF Testing.The MISCO digital refractometer is the ideal instrument for testing DEF to prevent the use of fluid that is outside expected values. MISCO refractometers meet or exceed the requirements of ASTM D7821 - 12, Standard Test Method for Field Test Determination of Urea Concentration in Diesel Exhaust Fluid (DEF).The American Petroleum Institute (API), a non-profit trade association and advocacy group for the petroleum and natural gas industry, is charged with certifying producers of Diesel Exhaust Fluid (DEF) for Selective Catalytic Reduction (SCR) equipped diesel engines in North America. The best way to ensure a good DEF fluid is to only purchase urea which carries API certification and frequently test the fluid with a MISCO refractometer to make sure that it meets quality specifications. Misco PA202X-185-629 SpecificationOptic MaterialSapphireDetector Elements1,024Well/Sample Area MaterialStainless SteelEvaporation CoverYESLight SourcePrecision LED @ 589 nmDisplay TypeLCDDisplay Characters24 Characters - 2 LinesDisplay BacklightYESDisplay LanguageEnglish, German, Spanish, French, Italian, RussianScale# 185Urea % w/wRange: 0 to 51Resolution: 0.1Precision: 0.1Scale# 629Urea (nD20)Range: 1.3330 to 1.4140Resolution: 0.0001Precision: 0.0001Temperature RangeScale Dependent0 to 50 °C (32 to 122 °F) TypicalTemp. Control MethodAuto Temp. CorrectionTemp. Control BasisScale DependentPower Source2 AAA BatteriesBattery LifeApprox. 5,000 ReadingsBody ColorBLUE (2-Tone)Body MaterialPolymerWater ResistanceIP65 - Low Pressure WaterDimensions5.7 x 2.95 x 1.46 in. (145 x 75 x 37 mm)Weight8.8 Oz. (250 grams)User ProgrammableOptions/Settings, Select ScaleUser Calibration PointsTwoError CodesText BasedApprovals/CertificationsCECountry of OriginUSA
Price: 475 USD
Location: Casper, Wyoming
End Time: 2025-01-11T08:25:17.000Z
Shipping Cost: N/A USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 14 Days
Refund will be given as: Money Back
Brand: Misco
MPN: PA202X-185-629
Refractometer Type: Abbe Refractometer