Description: Industrial Air Pollution Monitoring by A.G. Clarke Developed from a short course taught at Leeds University, this book covers methods of monitoring emissions of air pollutants from stationary sources. It surveys the techniques and points out their advantages and disadvantages. FORMAT Paperback LANGUAGE English CONDITION Brand New Publisher Description Developed from a short course taught at Leeds University, this book covers methods of monitoring emissions of air pollutants from stationary sources. It surveys the techniques and points out their advantages and disadvantages. Table of Contents 1 Legislation on emissions of air pollutants and their monitoring.- 1.1 Why monitor emissions?.- 1.2 Emissions limits.- 1.3 Monitoring requirements.- 2 Gas composition calculations.- 2.1 Units.- 2.2 Wet and dry gas.- 2.3 Combustion fundamentals.- 2.4 The mole method of calculation for gases.- 2.5 Combustion and emissions calculations for solid and liquid fuels or wastes.- 2.6 Calculations based on flue gas analysis.- 3 Particulate emissions by extractive sampling.- 3.1 Introduction.- 3.2 Basic principles.- 3.3 Equipment.- 3.4 Practical aspects of sampling.- 4 Particulate emissions - optical and other methods for continuous monitoring from a point source.- 4.1 The definition of particulate emissions.- 4.2 Design of optical devices for continuous measurement.- 4.3 Other techniques for continuous measurement.- 4.4 Interaction of light with particles.- 4.5 Practical limitations.- 4.6 Summary.- 5 Gas sampling and conditioning.- 5.1 General considerations.- 5.2 Representative sampling.- 5.3 Sampling probes and transfer lines.- 5.4 Sample conditioning.- 5.5 Other features.- 6 Batch sampling and wet chemical methods of analysis.- 6.1 Introduction.- 6.2 Moisture.- 6.3 Simple combustion gases.- 6.4 Other gas chromatography applications.- 6.5 Aqueous absorption and wet chemical analysis.- 6.6 Sulphur compounds.- 6.7 Nitrogen compounds.- 6.8 Halogen compounds.- 6.9 Metals.- 7 Optical methods of analysis. 1 Infra-red.- 7.1 Introduction.- 7.2 Infra-red spectra of typical polluting gases.- 7.3 Types of analyser.- 7.4 Comparison between extractive and cross-duct systems.- 7.5 Conclusions.- 8 Optical methods of gas analysis. 2 Visible and ultra-violet.- 8.1 Introduction.- 8.2 Ultra-violet/visible absorption principles.- 8.3 Practical NDUV analyser.- 8.4 Dispersive UV.- 8.5Chemiluminescent analysers.- 9 Volatile organics.- 9.1 Background.- 9.2 Sampling of organic compounds.- 9.3 Separating organic compounds.- 9.4 Analysis of organic compounds.- 10 Sampling and analysis of PAH, dioxins and furans.- 10.1 Introduction.- 10.2 Chemistry and toxicology.- 10.3 Emissions from combustion sources.- 10.4 Sampling.- 10.5 Analysis.- 10.6 Summary.- 11 Electrochemical and other non-optical techniques.- 11.1 Introduction.- 11.2 Methods for oxygen.- 11.3 Other low-temperature electrochemical cells.- 11.4 High-temperature electrochemical cells.- 11.5 Semiconductor sensors.- 11.6 Combustible gas detectors.- 11.7 Mass spectrometry.- 11.8 Ion mobility spectrometry.- 12 Calibration of continuous gaseous emission measuring systems.- 12.1 Introduction.- 12.2 Sampling and accuracy of CEMS.- 12.3 Types of CEMS and available calibration methods.- 12.4 Calibration with standard reference gas mixtures.- 12.5 Calibration using standard reference test methods.- 12.6 Calibration using verified CEMS.- 13 Calibration gases.- 13.1 Introduction.- 13.2 Calibration gas selection.- 13.3 Calibration gas mixture preparation.- 13.4 Static volumetric methods.- 13.5 Dynamic volumetric methods.- 13.6 Traceability.- 13.7 Traceability of calibration gas mixtures.- 13.8 Stability.- 13.9 Spectra Seal.- 14 Datalogging.- 14.1 Emission monitoring requirements.- 14.2 Methods of emission monitoring.- 14.3 Summary.- 15 Quality assurance and quality control in emissions monitoring.- 15.1 Introduction.- 15.2 Quality management for emissions monitoring.- 15.3 Organization and management.- 15.4 Quality systems.- 15.5 Staff.- 15.6 Equipment.- 15.7 Measurement traceability and calibration.- 15.8 Sample storage and transport.- 15.9 Quality audits and reviews.- 15.10 Common sources of error.-16 Statistics in relation to emissions monitoring.- 16.1 Introduction.- 16.2 The data.- 16.3 Fundamentals.- 16.4 Confidence limits.- 16.5 Hypothesis testing.- 16.6 Comparison of means.- 16.7 Statistics relating to the percentile points of a distribution.- Appendices.- A British Standards.- B German VDI Standards (Verein Deutscher Ingenieure).- C US EPA Standard Methods.- D Main provisions for testing to British Standard 3405: 1983.. Promotional Springer Book Archives Long Description Developed from a short course taught at Leeds University, this book covers methods of monitoring emissions of air pollutants from stationary sources. It surveys the techniques and points out their advantages and disadvantages. Details ISBN9401071438 Publisher Springer Language English Subtitle Gaseous and particulate emissions Edition 97199th ISBN-10 9401071438 ISBN-13 9789401071437 Short Title INDUSTRIAL AIR POLLUTION MONIT Media Book Year 2012 Publication Date 2012-06-16 Imprint Springer Place of Publication Dordrecht Country of Publication Netherlands DEWEY 333.7 Illustrations XIV, 306 p. Author A.G. Clarke Edited by A.G. Clarke Pages 306 Edition Description Softcover reprint of the original 1st ed. 1998 Series Environmental Management Series Format Paperback Alternative 9780412633904 Audience Professional & Vocational We've got this At The Nile, if you're looking for it, we've got it. With fast shipping, low prices, friendly service and well over a million items - you're bound to find what you want, at a price you'll love! TheNile_Item_ID:96396272;
Price: 314.31 AUD
Location: Melbourne
End Time: 2025-01-14T10:39:06.000Z
Shipping Cost: 9.4 AUD
Product Images
Item Specifics
Restocking fee: No
Return shipping will be paid by: Buyer
Returns Accepted: Returns Accepted
Item must be returned within: 30 Days
ISBN-13: 9789401071437
Book Title: Industrial Air Pollution Monitoring
Number of Pages: 306 Pages
Language: English
Publication Name: Industrial Air Pollution Monitoring
Publisher: Springer
Publication Year: 2012
Subject: Engineering & Technology, Chemistry
Item Height: 235 mm
Item Weight: 498 g
Type: Textbook
Author: A.G. Clarke
Item Width: 155 mm
Format: Paperback