Description: Climatedoctors.com OEM PartsSame Day ShippingCustomer SupportHoneywell FC37A1114 Electronic Air Cleaner Cell 16 x10 100% New OEM Parts Fast Shipping WELCOME TO OUR EBAY STORE climatedoctors Honeywell FC37A1114 Electronic Air Cleaner Cell 16 x10 FC37A1114 16 x 10 x 4½". Genuine Honeywell electronic air cleaner cell. Note, Honeywell 16 x 20" air cleaners use two cells. Assembled with ionizing wires and ready to slide in and use. Honeywell cells are symmetrical so they can be used with air flow going right or left. The cell is simply flipped around for the opposite air flow. Includes one plastic handle 137266. The handle can mount on either end of the cell allowing the cell to be rotated and used with air flow running in either direction.Determine the side of the cell that will be facing out before installing the handle. Since 1975 all F50A F50E F50F F300 use cells listed in the first 4 tabs above. The FC37A1171 is only used in the F52 grille mount. The current production cells are the same as the early cells that had the red fiberglass contact pad. The Honeywell cell can be identified by the part number stamped in to the aluminum. The text Honeywell Residentialis stamped in the end facing out and the part number is stamped in to a side edge, see photo below. The FC37A1114 is used in F300E1001 F300A1620 F50F1149. Collector Cell Washing We recommend soaking the collector cells. Soaking cleans better than the dishwasher and cleans better than a pressure washer. The cells typically do not need to be cleaned as often as the prefilters. After cleaning, inspect the cell plates for dirt, hold the cell up to light. View the plates through the ionizing section to see the dirtiest side. Note that only every other plate captures dirt. The plates are either charged or grounded. The charged particles are attracted to the grounded plates and repelled by the charged plates. Closely check the grounded plates, where as the charged plates will clean easily. Cleaning Ionizing Wires Honeywell recommends wiping down the ionizing wires when washing the collector cells. Also check the wires for roughness, a side effect of the corona discharge is the growth of a white quartz layer. Air near the high-voltage ionizer wires breaks down in to ions and high energy electrons. This mixture of ions and electrons is called the corona plasma. The ions collide with suspended particulate and confer the charge. The plasma has an unintended reaction with cyclomethicone, a silicone oil present in household products such as deodorant sprays and skin lotions. This reaction leaves deposits of solid silicon dioxide on the ionizing wires. These insulating formations will significantly suppress the corona pattern and intensity. Research has shown cleaning the wires with 600 grit emery cloth will remove the silicon dioxide. But at the risk of damaging the wire surface or breaking the wire. Cell Handle Installation The handle swings in to place and snaps in. Be sure to also snap down the locking tab. Fixing Cell Arcing If a cell is sparking, determine the sparking area and removed cell to inspect closer. To see the sparking, you may need to look in through the blower compartment or cut an inspection hole in the duct. An inspection window can also be used to see if cells need to be cleaned. A cell that is sparking randomly throughout is uncommon but could be caused by a film left behind from washing. If tobacco is not cleaned from a cell it can build up and cause random sparking. Diesel fumes can cause problems and are not easily cleaned. High altitude can make the air cleaner more susceptible to sparking. The collector plates should be cleaned to the bare shiny metal (stained is okay). Major cell sparking can be the result of power box wires getting crossed. The cell is powered by two voltages. The ionizing wires receive 8kv and the plates get 4kv. If these voltages get crossed, then the cell will spark all over and much louder than normal. If a cell is shorted and keeps the neon lamp from coming on, then inspect for damage. The most common short is from the aluminum dividers in between the ionizing wires. These dividers can get pushed in to the collector plates, they should not touch the plates. A dent across several plates causing them to touch would be a simple short to find. A dandling ionizing wire can cause a short. Continuous Cell Arcing The 4074EHG tabs make contact with the edge of every other cell plate. Photo right shows the edges of the plates burnt down far enough, that the contact shorts against every plate and not every other. Honeywell cells can last for decades, but continuous sparking can cause damage. A cell may spark continuous if collector plate spacing gets too close. The spacing can become uneven when a cell gets pushed out of square, twisted, a dent, etc. One common problem is a loose plate that has lost the press fit with its horizontal rods. The loose plate likely had continuous sparking that created surges of current through the press fit. The current surges resulted in sparks that brunt away the press fit. This cell would not be repairable. When one cell has been subject to excessive sparking, then both cells will be burnt under the contact pad. This is because a spark in one cell will cause a current surge that is drawn from both cells. Check the contact pad to determine the condition of the cell. If your cells have badly burnt contacts as in the photo above, then it is best to replace the cells. When a cell has been subjected to excessive sparking, the press fit of all the plates will first be weakened. The sparking at these connections causes corrosion from ozone. The aluminum around the press fit becomes corroded and no longer conducts as well. The cell contacts operate at high voltage and are not a sensitive connection. The contact does not require cleaning. The contact is tin coated copper. Sandpaper will remove the tin coating. Cell Contains 3 Contacts but Only 2 Used You may have noticed there are 3 contacts on the cell pad but only two contacts at the power box. This allows the F50-F300 to be installed with either right or left air flow. The cell can be rotated allowing an installation with opposite air flow. Only two contacts are used, the center contact and one end contact. Photo animation shows when the cell is rotated, the contacts maintain the correct connections. The center contact powers the ionizing wires. The two outside contacts are connected and power the collector plates. Genuine Honeywell FC37A1114 electronic air cleaner cell. 16 x 10 x 4 1/2". * Note, Honeywell 16 x 20" air cleaners use two cells. Assembled with ionizing wires and ready to slide in and use. Honeywell cells are symmetrical so they can be used with air flow going right or left. The cell is simply flipped around for the opposite air flow. Includes one plastic handle 137266. The handle can mount on either end of the cell allowing the cell to be rotated and used with air flow running in either direction. Determine the side of the cell that will be facing out before installing the handle. The FC37A1114 is used in F300E1001, F300A1620, F50F1149. Payment Shipping Returns Refunds Contact Us About Us Payment Shipping Returns Refunds Contact Us About Us We accept PayPal, wire transfers, and all major credit cards (Visa, MasterCard, American Express and Discover), as well as debit cards. For assistance with payment questions, quotes, and volume discounts, contact our Customer Support during normal business hours. **Please note that ClimateDoctors is required to charge 7.63% sales tax for shipments to Colorado addresses. We combine shipping when possible. All orders usually ship within 1 business day if placed before 3 p.m. EST. Shipment days are Monday through Friday. Tracking information is sent to you automatically at the time of shipment and is always available if needed. All orders are inspected prior to shipment and are insured against loss or damage in transit. All international customers are responsible for and duties and broker fees. Standard US shipping rates do not include Alaska and Hawaii. Please contact us for a shipping quote to these destinations. If there are any questions, please ask before you make a purchase and/or bid. Return Eligibility You may return most new, unopened items for a refund within 30 days of sale. All returns will be subject to a 20% restocking fee. These items should be in their original packaging and have their serial number or UPC intact. You must return items in new or unused condition with all original materials included with the shipment; thus, the merchandise must be returned in resalable condition: complete in original packaging, unused, and free from damage. All Item(s) must be returned in original condition, undamaged, unopened, unused and uncut complete in original packaging. Returns will not be accepted on items that are:Opened or usedItems cannot be returned once installedMissing their serial number or UPCNon-Returnable ItemsReturned more than 30 days after deliveryReturned without notification Tools and Meters are exchangeable within 3 days of receipt. Non-Returnable Items Policy Some of our products by their very nature are not returnable. The following items are non-returnable and do not qualify for refunds or exchanges:Replacement PartsRefrigerantCompressorsEquipmentElectrical Parts/ComponentsHeating Parts/ComponentsA/C Parts If you have a non-returnable item that arrived damaged or defective please contact us immediately. Restocking Fee All returns are subject to a 20% restocking fee unless other arrangements have been discussed prior to the return being sent in. Return Instructions To return new condition items by mail, send us an email and have your packing slip or order number handy. Once your return is approved, we will provide a return address, and you will receive a Return Merchandise Authorization (RMA) number that you'll write directly on your shipment box. Finally, mail the packing slip along with purchased items, all their contents, and product packaging to the address provided to you. We must receive your returned items within 45 days of the date of sale (see Non-Returnable Items for exceptions). Damage may happen during shipping, and we apologize for the inconvenience this may cause. Please contact customer service if you have received damaged goods, and we will assist you immediately. We inspect all returned items when they arrive at our processing facility. If your return is a result of an error on the part of Climatedoctors, we will refund the full cost of the merchandise and original shipping charges. If you return an item that was opened or shows signs of wear, that item is not eligible for a refund. Products must be received at our returns processing facility before 30 days from the date of sale. You can expect your refund within four weeks from the date you return your package. In most cases you will receive a refund sooner, but we estimate four weeks because of the time required for return shipping (up to 14 days), product inspection at our returns facility (up to 5 business days), and processing from your bank or credit card company (up to 5 business days). All refunds are issued to the original method of payment unless you selected to return for in-store credit. Once your return is processed we will send you an email with your refund details. Error Corrections & Term Amendments Clerical or typographical errors may be found on this site. We reserve the right to correct any errors, inaccuracies, or omissions, and to amend our Return Policy and any information on our website at any time. Climate Doctors is committed to providing you with the best customer service and HVAC/R product knowledge in the industry. Our friendly Team is ready to help answer all your parts questions! Sales or Product Specialists are available: Monday-Friday: 9:00 a.m. to 5:00 p.m. CST. Climatedoctors serves both trade professionals and homeowners with the very best of brand name heating, air-conditioning (HVAC), refrigeration, HVAC equipment, tools and supplies. We can help with everything from large commercial projects to residential heating and air. We're family owned and have continued to build our business on a firm foundation of integrity, commitment and trust. We're big enough to provide a wide selection and competitive prices, but small enough to be flexible and responsive. Our family members (as we call our employees) develop long-term personal relationships with our customers. Some of our clients say that we know their needs almost better than they do, so let us begin to cure all of your comfort needs! 100% New OEM Parts Fast Shipping Click here to see description BUY NOW!PaymentShippingReturnsPaymentShippingReturns We accept PayPal, wire transfers, and all major credit cards (Visa, MasterCard, American Express and Discover), as well as debit cards. For assistance with payment questions, quotes, and volume discounts, contact our Customer Support during normal business hours. If you purchase from us directly, we DO NOT charge sales tax. We offer Same Day shipping on all orders! We combine shipping when possible. All orders usually ship within 1 business day if placed before 2 p.m. EST. Shipment days are Monday through Friday. Tracking information is sent to you automatically at the time of shipment and is always available if needed. All orders are inspected prior to shipment and are insured against loss or damage in transit. All international customers are responsible for duties and broker fees. Standard US shipping rates do not include Alaska and Hawaii. Please contact us for a shipping quote to these destinations. If there are any questions, please ask before you make a purchase and/or bid. If you are not 100% satisfied with your purchase, you can return the product and get a refund or exchange the product for another one, be it similar or not. You can return a product for up to 30 days from the date you purchased it. Any product you return must be in the same condition you received it and in the original packaging. All items are subject to a 20% restocking fee on new and unused items.OEM PartsSame Day ShippingCustomer Support100% New OEM Parts Fast Shipping WELCOME TO OUR EBAY STORE climatedoctors Honeywell FC37A1114 Electronic Air Cleaner Cell 16 x10 FC37A1114 16 x 10 x 4½". Genuine Honeywell electronic air cleaner cell. Note, Honeywell 16 x 20" air cleaners use two cells. Assembled with ionizing wires and ready to slide in and use. Honeywell cells are symmetrical so they can be used with air flow going right or left. The cell is simply flipped around for the opposite air flow. Includes one plastic handle 137266. The handle can mount on either end of the cell allowing the cell to be rotated and used with air flow running in either direction. Determine the side of the cell that will be facing out before installing the handle. Since 1975 all F50A F50E F50F F300 use cells listed in the first 4 tabs above. The FC37A1171 is only used in the F52 grille mount. The current production cells are the same as the early cells that had the red fiberglass contact pad. The Honeywell cell can be identified by the part number stamped in to the aluminum. The text Honeywell Residentialis stamped in the end facing out and the part number is stamped in to a side edge, see photo below. The FC37A1114 is used in F300E1001 F300A1620 F50F1149. Collector Cell Washing We recommend soaking the collector cells. Soaking cleans better than the dishwasher and cleans better than a pressure washer. The cells typically do not need to be cleaned as often as the prefilters. After cleaning, inspect the cell plates for dirt, hold the cell up to light. View the plates through the ionizing section to see the dirtiest side. Note that only every other plate captures dirt. The plates are either charged or grounded. The charged particles are attracted to the grounded plates and repelled by the charged plates. Closely check the grounded plates, where as the charged plates will clean easily. Cleaning Ionizing Wires Honeywell recommends wiping down the ionizing wires when washing the collector cells. Also check the wires for roughness, a side effect of the corona discharge is the growth of a white quartz layer. Air near the high-voltage ionizer wires breaks down in to ions and high energy electrons. This mixture of ions and electrons is called the corona plasma. The ions collide with suspended particulate and confer the charge. The plasma has an unintended reaction with cyclomethicone, a silicone oil present in household products such as deodorant sprays and skin lotions. This reaction leaves deposits of solid silicon dioxide on the ionizing wires. These insulating formations will significantly suppress the corona pattern and intensity. Research has shown cleaning the wires with 600 grit emery cloth will remove the silicon dioxide. But at the risk of damaging the wire surface or breaking the wire. Cell Handle Installation The handle swings in to place and snaps in. Be sure to also snap down the locking tab. Fixing Cell Arcing If a cell is sparking, determine the sparking area and removed cell to inspect closer. To see the sparking, you may need to look in through the blower compartment or cut an inspection hole in the duct. An inspection window can also be used to see if cells need to be cleaned. A cell that is sparking randomly throughout is uncommon but could be caused by a film left behind from washing. If tobacco is not cleaned from a cell it can build up and cause random sparking. Diesel fumes can cause problems and are not easily cleaned. High altitude can make the air cleaner more susceptible to sparking. The collector plates should be cleaned to the bare shiny metal (stained is okay). Major cell sparking can be the result of power box wires getting crossed. The cell is powered by two voltages. The ionizing wires receive 8kv and the plates get 4kv. If these voltages get crossed, then the cell will spark all over and much louder than normal. If a cell is shorted and keeps the neon lamp from coming on, then inspect for damage. The most common short is from the aluminum dividers in between the ionizing wires. These dividers can get pushed in to the collector plates, they should not touch the plates. A dent across several plates causing them to touch would be a simple short to find. A dandling ionizing wire can cause a short. Continuous Cell Arcing The 4074EHG tabs make contact with the edge of every other cell plate. Photo right shows the edges of the plates burnt down far enough, that the contact shorts against every plate and not every other. Honeywell cells can last for decades, but continuous sparking can cause damage. A cell may spark continuous if collector plate spacing gets too close. The spacing can become uneven when a cell gets pushed out of square, twisted, a dent, etc. One common problem is a loose plate that has lost the press fit with its horizontal rods. The loose plate likely had continuous sparking that created surges of current through the press fit. The current surges resulted in sparks that brunt away the press fit. This cell would not be repairable. When one cell has been subject to excessive sparking, then both cells will be burnt under the contact pad. This is because a spark in one cell will cause a current surge that is drawn from both cells. Check the contact pad to determine the condition of the cell. If your cells have badly burnt contacts as in the photo above, then it is best to replace the cells. When a cell has been subjected to excessive sparking, the press fit of all the plates will first be weakened. The sparking at these connections causes corrosion from ozone. The aluminum around the press fit becomes corroded and no longer conducts as well. The cell contacts operate at high voltage and are not a sensitive connection. The contact does not require cleaning. The contact is tin coated copper. Sandpaper will remove the tin coating. Cell Contains 3 Contacts but Only 2 Used You may have noticed there are 3 contacts on the cell pad but only two contacts at the power box. This allows the F50-F300 to be installed with either right or left air flow. The cell can be rotated allowing an installation with opposite air flow. Only two contacts are used, the center contact and one end contact. Photo animation shows when the cell is rotated, the contacts maintain the correct connections. The center contact powers the ionizing wires. The two outside contacts are connected and power the collector plates. Genuine Honeywell FC37A1114 electronic air cleaner cell. 16 x 10 x 4 1/2". * Note, Honeywell 16 x 20" air cleaners use two cells. Assembled with ionizing wires and ready to slide in and use. Honeywell cells are symmetrical so they can be used with air flow going right or left. The cell is simply flipped around for the opposite air flow. Includes one plastic handle 137266. The handle can mount on either end of the cell allowing the cell to be rotated and used with air flow running in either direction. Determine the side of the cell that will be facing out before installing the handle. The FC37A1114 is used in F300E1001, F300A1620, F50F1149. Payment Shipping Returns Refunds Contact Us About Us Payment Shipping Returns Refunds Contact Us About Us We accept PayPal, wire transfers, and all major credit cards (Visa, MasterCard, American Express and Discover), as well as debit cards. For assistance with payment questions, quotes, and volume discounts, contact our Customer Support during normal business hours. **Please note that ClimateDoctors is required to charge 7.63% sales tax for shipments to Colorado addresses. We combine shipping when possible. All orders usually ship within 1 business day if placed before 3 p.m. EST. Shipment days are Monday through Friday. Tracking information is sent to you automatically at the time of shipment and is always available if needed. All orders are inspected prior to shipment and are insured against loss or damage in transit. All international customers are responsible for and duties and broker fees. Standard US shipping rates do not include Alaska and Hawaii. Please contact us for a shipping quote to these destinations. If there are any questions, please ask before you make a purchase and/or bid. Return Eligibility You may return most new, unopened items for a refund within 30 days of sale. All returns will be subject to a 20% restocking fee. These items should be in their original packaging and have their serial number or UPC intact. You must return items in new or unused condition with all original materials included with the shipment; thus, the merchandise must be returned in resalable condition: complete in original packaging, unused, and free from damage. All Item(s) must be returned in original condition, undamaged, unopened, unused and uncut complete in original packaging. Returns will not be accepted on items that are: ---Opened or used ---Items cannot be returned once installed ---Missing their serial number or UPC ---Non-Returnable Items ---Returned more than 30 days after delivery ---Returned without notification Tools and Meters are exchangeable within 3 days of receipt. Non-Returnable Items Policy Some of our products by their very nature are not returnable. The following items are non-returnable and do not qualify for refunds or exchanges: ---Replacement Parts ---Refrigerant ---Compressors ---Equipment ---Electrical Parts/Components ---Heating Parts/Components ---A/C Parts If you have a non-returnable item that arrived damaged or defective please contact us immediately. Restocking Fee All returns are subject to a 20% restocking fee unless other arrangements have been discussed prior to the return being sent in. Return Instructions To return new condition items by mail, send us an email and have your packing slip or order number handy. Once your return is approved, we will provide a return address, and you will receive a Return Merchandise Authorization (RMA) number that you'll write directly on your shipment box. Finally, mail the packing slip along with purchased items, all their contents, and product packaging to the address provided to you. We must receive your returned items within 45 days of the date of sale (see Non-Returnable Items for exceptions). Damage may happen during shipping, and we apologize for the inconvenience this may cause. Please contact customer service if you have received damaged goods, and we will assist you immediately. We inspect all returned items when they arrive at our processing facility. If your return is a result of an error on the part of Climatedoctors, we will refund the full cost of the merchandise and original shipping charges. If you return an item that was opened or shows signs of wear, that item is not eligible for a refund. Products must be received at our returns processing facility before 30 days from the date of sale. You can expect your refund within four weeks from the date you return your package. In most cases you will receive a refund sooner, but we estimate four weeks because of the time required for return shipping (up to 14 days), product inspection at our returns facility (up to 5 business days), and processing from your bank or credit card company (up to 5 business days). All refunds are issued to the original method of payment unless you selected to return for in-store credit. Once your return is processed we will send you an email with your refund details. Error Corrections & Term Amendments Clerical or typographical errors may be found on this site. We reserve the right to correct any errors, inaccuracies, or omissions, and to amend our Return Policy and any information on our website at any time. Climate Doctors is committed to providing you with the best customer service and HVAC/R product knowledge in the industry. Our friendly Team is ready to help answer all your parts questions! Sales or Product Specialists are available: Monday-Friday: 9:00 a.m. to 5:00 p.m. CST. Climatedoctors serves both trade professionals and homeowners with the very best of brand name heating, air-conditioning (HVAC), refrigeration, HVAC equipment, tools and supplies. We can help with everything from large commercial projects to residential heating and air. We're family owned and have continued to build our business on a firm foundation of integrity, commitment and trust. We're big enough to provide a wide selection and competitive prices, but small enough to be flexible and responsive. Our family members (as we call our employees) develop long-term personal relationships with our customers. Some of our clients say that we know their needs almost better than they do, so let us begin to cure all of your comfort needs! 100% New OEM Parts Fast Shipping Click here to see description Climatedoctors.com Honeywell FC37A1114 Electronic Air Cleaner Cell 16 x10 100% New OEM Parts Fast Shipping WELCOME TO OUR EBAY STORE climatedoctors Honeywell FC37A1114 Electronic Air Cleaner Cell 16 x10 FC37A1114 16 x 10 x 4½". Genuine Honeywell electronic air cleaner cell. Note, Honeywell 16 x 20" air cleaners use two cells. Assembled with ionizing wires and ready to slide in and use. Honeywell cells are symmetrical so they can be used with air flow going right or left. The cell is simply flipped around for the opposite air flow. Includes one plastic handle 137266. The handle can mount on either end of the cell allowing the cell to be rotated and used with air flow running in either direction.Determine the side of the cell that will be facing out before installing the handle. Since 1975 all F50A F50E F50F F300 use cells listed in the first 4 tabs above. The FC37A1171 is only used in the F52 grille mount. The current production cells are the same as the early cells that had the red fiberglass contact pad. The Honeywell cell can be identified by the part number stamped in to the aluminum. The text Honeywell Residentialis stamped in the end facing out and the part number is stamped in to a side edge, see photo below. The FC37A1114 is used in F300E1001 F300A1620 F50F1149. Collector Cell Washing We recommend soaking the collector cells. Soaking cleans better than the dishwasher and cleans better than a pressure washer. The cells typically do not need to be cleaned as often as the prefilters. After cleaning, inspect the cell plates for dirt, hold the cell up to light. View the plates through the ionizing section to see the dirtiest side. Note that only every other plate captures dirt. The plates are either charged or grounded. The charged particles are attracted to the grounded plates and repelled by the charged plates. Closely check the grounded plates, where as the charged plates will clean easily. Cleaning Ionizing Wires Honeywell recommends wiping down the ionizing wires when washing the collector cells. Also check the wires for roughness, a side effect of the corona discharge is the growth of a white quartz layer. Air near the high-voltage ionizer wires breaks down in to ions and high energy electrons. This mixture of ions and electrons is called the corona plasma. The ions collide with suspended particulate and confer the charge. The plasma has an unintended reaction with cyclomethicone, a silicone oil present in household products such as deodorant sprays and skin lotions. This reaction leaves deposits of solid silicon dioxide on the ionizing wires. These insulating formations will significantly suppress the corona pattern and intensity. Research has shown cleaning the wires with 600 grit emery cloth will remove the silicon dioxide. But at the risk of damaging the wire surface or breaking the wire. Cell Handle Installation The handle swings in to place and snaps in. Be sure to also snap down the locking tab. Fixing Cell Arcing If a cell is sparking, determine the sparking area and removed cell to inspect closer. To see the sparking, you may need to look in through the blower compartment or cut an inspection hole in the duct. An inspection window can also be used to see if cells need to be cleaned. A cell that is sparking randomly throughout is uncommon but could be caused by a film left behind from washing. If tobacco is not cleaned from a cell it can build up and cause random sparking. Diesel fumes can cause problems and are not easily cleaned. High altitude can make the air cleaner more susceptible to sparking. The collector plates should be cleaned to the bare shiny metal (stained is okay). Major cell sparking can be the result of power box wires getting crossed. The cell is powered by two voltages. The ionizing wires receive 8kv and the plates get 4kv. If these voltages get crossed, then the cell will spark all over and much louder than normal. If a cell is shorted and keeps the neon lamp from coming on, then inspect for damage. The most common short is from the aluminum dividers in between the ionizing wires. These dividers can get pushed in to the collector plates, they should not touch the plates. A dent across several plates causing them to touch would be a simple short to find. A dandling ionizing wire can cause a short. Continuous Cell Arcing The 4074EHG tabs make contact with the edge of every other cell plate. Photo right shows the edges of the plates burnt down far enough, that the contact shorts against every plate and not every other. Honeywell cells can last for decades, but continuous sparking can cause damage. A cell may spark continuous if collector plate spacing gets too close. The spacing can become uneven when a cell gets pushed out of square, twisted, a dent, etc. One common problem is a loose plate that has lost the press fit with its horizontal rods. The loose plate likely had continuous sparking that created surges of current through the press fit. The current surges resulted in sparks that brunt away the press fit. This cell would not be repairable. When one cell has been subject to excessive sparking, then both cells will be burnt under the contact pad. This is because a spark in one cell will cause a current surge that is drawn from both cells. Check the contact pad to determine the condition of the cell. If your cells have badly burnt contacts as in the photo above, then it is best to replace the cells. When a cell has been subjected to excessive sparking, the press fit of all the plates will first be weakened. The sparking at these connections causes corrosion from ozone. The aluminum around the press fit becomes corroded and no longer conducts as well. The cell contacts operate at high voltage and are not a sensitive connection. The contact does not require cleaning. The contact is tin coated copper. Sandpaper will remove the tin coating. Cell Contains 3 Contacts but Only 2 Used You may have noticed there are 3 contacts on the cell pad but only two contacts at the power box. This allows the F50-F300 to be installed with either right or left air flow. The cell can be rotated allowing an installation with opposite air flow. Only two contacts are used, the center contact and one end contact. Photo animation shows when the cell is rotated, the contacts maintain the correct connections. The center contact powers the ionizing wires. The two outside contacts are connected and power the collector plates. Genuine Honeywell FC37A1114 electronic air cleaner cell. 16 x 10 x 4 1/2". * Note, Honeywell 16 x 20" air cleaners use two cells. Assembled with ionizing wires and ready to slide in and use. Honeywell cells are symmetrical so they can be used with air flow going right or left. The cell is simply flipped around for the opposite air flow. Includes one plastic handle 137266. The handle can mount on either end of the cell allowing the cell to be rotated and used with air flow running in either direction. Determine the side of the cell that will be facing out before installing the handle. The FC37A1114 is used in F300E1001, F300A1620, F50F1149. Payment Shipping Returns Refunds Contact Us About Us Payment Shipping Returns Refunds Contact Us About Us We accept PayPal, wire transfers, and all major credit cards (Visa, MasterCard, American Express and Discover), as well as debit cards. For assistance with payment questions, quotes, and volume discounts, contact our Customer Support during normal business hours. **Please note that ClimateDoctors is required to charge 7.63% sales tax for shipments to Colorado addresses. We combine shipping when possible. All orders usually ship within 1 business day if placed before 3 p.m. EST. Shipment days are Monday through Friday. Tracking information is sent to you automatically at the time of shipment and is always available if needed. All orders are inspected prior to shipment and are insured against loss or damage in transit. All international customers are responsible for and duties and broker fees. Standard US shipping rates do not include Alaska and Hawaii. Please contact us for a shipping quote to these destinations. If there are any questions, please ask before you make a purchase and/or bid. Return Eligibility You may return most new, unopened items for a refund within 30 days of sale. All returns will be subject to a 20% restocking fee. These items should be in their original packaging and have their serial number or UPC intact. You must return items in new or unused condition with all original materials included with the shipment; thus, the merchandise must be returned in resalable condition: complete in original packaging, unused, and free from damage. All Item(s) must be returned in original condition, undamaged, unopened, unused and uncut complete in original packaging. Returns will not be accepted on items that are:Opened or usedItems cannot be returned once installedMissing their serial number or UPCNon-Returnable ItemsReturned more than 30 days after deliveryReturned without notification Tools and Meters are exchangeable within 3 days of receipt. Non-Returnable Items Policy Some of our products by their very nature are not returnable. The following items are non-returnable and do not qualify for refunds or exchanges:Replacement PartsRefrigerantCompressorsEquipmentElectrical Parts/ComponentsHeating Parts/ComponentsA/C Parts If you have a non-returnable item that arrived damaged or defective please contact us immediately. Restocking Fee All returns are subject to a 20% restocking fee unless other arrangements have been discussed prior to the return being sent in. Return Instructions To return new condition items by mail, send us an email and have your packing slip or order number handy. Once your return is approved, we will provide a return address, and you will receive a Return Merchandise Authorization (RMA) number that you'll write directly on your shipment box. Finally, mail the packing slip along with purchased items, all their contents, and product packaging to the address provided to you. We must receive your returned items within 45 days of the date of sale (see Non-Returnable Items for exceptions). Damage may happen during shipping, and we apologize for the inconvenience this may cause. Please contact customer service if you have received damaged goods, and we will assist you immediately. We inspect all returned items when they arrive at our processing facility. If your return is a result of an error on the part of Climatedoctors, we will refund the full cost of the merchandise and original shipping charges. If you return an item that was opened or shows signs of wear, that item is not eligible for a refund. Products must be received at our returns processing facility before 30 days from the date of sale. You can expect your refund within four weeks from the date you return your package. In most cases you will receive a refund sooner, but we estimate four weeks because of the time required for return shipping (up to 14 days), product inspection at our returns facility (up to 5 business days), and processing from your bank or credit card company (up to 5 business days). All refunds are issued to the original method of payment unless you selected to return for in-store credit. Once your return is processed we will send you an email with your refund details. Error Corrections & Term Amendments Clerical or typographical errors may be found on this site. We reserve the right to correct any errors, inaccuracies, or omissions, and to amend our Return Policy and any information on our website at any time. Climate Doctors is committed to providing you with the best customer service and HVAC/R product knowledge in the industry. Our friendly Team is ready to help answer all your parts questions! Sales or Product Specialists are available: Monday-Friday: 9:00 a.m. to 5:00 p.m. CST. Climatedoctors serves both trade professionals and homeowners with the very best of brand name heating, air-conditioning (HVAC), refrigeration, HVAC equipment, tools and supplies. We can help with everything from large commercial projects to residential heating and air. We're family owned and have continued to build our business on a firm foundation of integrity, commitment and trust. We're big enough to provide a wide selection and competitive prices, but small enough to be flexible and responsive. Our family members (as we call our employees) develop long-term personal relationships with our customers. Some of our clients say that we know their needs almost better than they do, so let us begin to cure all of your comfort needs! 100% New OEM Parts Fast Shipping Click here to see description BUY NOW!Payment We accept PayPal, wire transfers, and all major credit cards (Visa, MasterCard, American Express and Discover), as well as debit cards. For assistance with payment questions, quotes, and volume discounts, contact our Customer Support during normal business hours. If you purchase from us directly, we DO NOT charge sales tax.Shipping We offer Same Day shipping on all orders! We combine shipping when possible. All orders usually ship within 1 business day if placed before 2 p.m. EST. Shipment days are Monday through Friday. Tracking information is sent to you automatically at the time of shipment and is always available if needed. All orders are inspected prior to shipment and are insured against loss or damage in transit. All international customers are responsible for duties and broker fees. Standard US shipping rates do not include Alaska and Hawaii. Please contact us for a shipping quote to these destinations. If there are any questions, please ask before you make a purchase and/or bid. Returns If you are not 100% satisfied with your purchase, you can return the product and get a refund or exchange the product for another one, be it similar or not. You can return a product for up to 30 days from the date you purchased it. Any product you return must be in the same condition you received it and in the original packaging. All items are subject to a 20% restocking fee on new and unused items.OEM PartsSame Day ShippingCustomer Support 100% New OEM Parts Fast Shipping WELCOME TO OUR EBAY STORE climatedoctors Honeywell FC37A1114 Electronic Air Cleaner Cell 16 x10 FC37A1114 16 x 10 x 4½". Genuine Honeywell electronic air cleaner cell. Note, Honeywell 16 x 20" air cleaners use two cells. Assembled with ionizing wires and ready to slide in and use. Honeywell cells are symmetrical so they can be used with air flow going right or left. The cell is simply flipped around for the opposite air flow. Includes one plastic handle 137266. The handle can mount on either end of the cell allowing the cell to be rotated and used with air flow running in either direction.Determine the side of the cell that will be facing out before installing the handle. Since 1975 all F50A F50E F50F F300 use cells listed in the first 4 tabs above. The FC37A1171 is only used in the F52 grille mount. The current production cells are the same as the early cells that had the red fiberglass contact pad. The Honeywell cell can be identified by the part number stamped in to the aluminum. The text Honeywell Residentialis stamped in the end facing out and the part number is stamped in to a side edge, see photo below. The FC37A1114 is used in F300E1001 F300A1620 F50F1149. Collector Cell Washing We recommend soaking the collector cells. Soaking cleans better than the dishwasher and cleans better than a pressure washer. The cells typically do not need to be cleaned as often as the prefilters. After cleaning, inspect the cell plates for dirt, hold the cell up to light. View the plates through the ionizing section to see the dirtiest side. Note that only every other plate captures dirt. The plates are either charged or grounded. The charged particles are attracted to the grounded plates and repelled by the charged plates. Closely check the grounded plates, where as the charged plates will clean easily. Cleaning Ionizing Wires Honeywell recommends wiping down the ionizing wires when washing the collector cells. Also check the wires for roughness, a side effect of the corona discharge is the growth of a white quartz layer. Air near the high-voltage ionizer wires breaks down in to ions and high energy electrons. This mixture of ions and electrons is called the corona plasma. The ions collide with suspended particulate and confer the charge. The plasma has an unintended reaction with cyclomethicone, a silicone oil present in household products such as deodorant sprays and skin lotions. This reaction leaves deposits of solid silicon dioxide on the ionizing wires. These insulating formations will significantly suppress the corona pattern and intensity. Research has shown cleaning the wires with 600 grit emery cloth will remove the silicon dioxide. But at the risk of damaging the wire surface or breaking the wire. Cell Handle Installation The handle swings in to place and snaps in. Be sure to also snap down the locking tab. Fixing Cell Arcing If a cell is sparking, determine the sparking area and removed cell to inspect closer. To see the sparking, you may need to look in through the blower compartment or cut an inspection hole in the duct. An inspection window can also be used to see if cells need to be cleaned. A cell that is sparking randomly throughout is uncommon but could be caused by a film left behind from washing. If tobacco is not cleaned from a cell it can build up and cause random sparking. Diesel fumes can cause problems and are not easily cleaned. High altitude can make the air cleaner more susceptible to sparking. The collector plates should be cleaned to the bare shiny metal (stained is okay). Major cell sparking can be the result of power box wires getting crossed. The cell is powered by two voltages. The ionizing wires receive 8kv and the plates get 4kv. If these voltages get crossed, then the cell will spark all over and much louder than normal. If a cell is shorted and keeps the neon lamp from coming on, then inspect for damage. The most common short is from the aluminum dividers in between the ionizing wires. These dividers can get pushed in to the collector plates, they should not touch the plates. A dent across several plates causing them to touch would be a simple short to find. A dandling ionizing wire can cause a short. Continuous Cell Arcing The 4074EHG tabs make contact with the edge of every other cell plate. Photo right shows the edges of the plates burnt down far enough, that the contact shorts against every plate and not every other. Honeywell cells can last for decades, but continuous sparking can cause damage. A cell may spark continuous if collector plate spacing gets too close. The spacing can become uneven when a cell gets pushed out of square, twisted, a dent, etc. One common problem is a loose plate that has lost the press fit with its horizontal rods. The loose plate likely had continuous sparking that created surges of current through the press fit. The current surges resulted in sparks that brunt away the press fit. This cell would not be repairable. When one cell has been subject to excessive sparking, then both cells will be burnt under the contact pad. This is because a spark in one cell will cause a current surge that is drawn from both cells. Check the contact pad to determine the condition of the cell. If your cells have badly burnt contacts as in the photo above, then it is best to replace the cells. When a cell has been subjected to excessive sparking, the press fit of all the plates will first be weakened. The sparking at these connections causes corrosion from ozone. The aluminum around the press fit becomes corroded and no longer conducts as well. The cell contacts operate at high voltage and are not a sensitive connection. The contact does not require cleaning. The contact is tin coated copper. Sandpaper will remove the tin coating. Cell Contains 3 Contacts but Only 2 Used You may have noticed there are 3 contacts on the cell pad but only two contacts at the power box. This allows the F50-F300 to be installed with either right or left air flow. The cell can be rotated allowing an installation with opposite air flow. Only two contacts are used, the center contact and one end contact. Photo animation shows when the cell is rotated, the contacts maintain the correct connections. The center contact powers the ionizing wires. The two outside contacts are connected and power the collector plates. Genuine Honeywell FC37A1114 electronic air cleaner cell. 16 x 10 x 4 1/2". * Note, Honeywell 16 x 20" air cleaners use two cells. Assembled with ionizing wires and ready to slide in and use. Honeywell cells are symmetrical so they can be used with air flow going right or left. The cell is simply flipped around for the opposite air flow. Includes one plastic handle 137266. The handle can mount on either end of the cell allowing the cell to be rotated and used with air flow running in either direction. Determine the side of the cell that will be facing out before installing the handle. The FC37A1114 is used in F300E1001, F300A1620, F50F1149. Payment Shipping Returns Refunds Contact Us About Us Payment Shipping Returns Refunds Contact Us About Us We accept PayPal, wire transfers, and all major credit cards (Visa, MasterCard, American Express and Discover), as well as debit cards. For assistance with payment questions, quotes, and volume discounts, contact our Customer Support during normal business hours. **Please note that ClimateDoctors is required to charge 7.63% sales tax for shipments to Colorado addresses. We combine shipping when possible. All orders usually ship within 1 business day if placed before 3 p.m. EST. Shipment days are Monday through Friday. Tracking information is sent to you automatically at the time of shipment and is always available if needed. All orders are inspected prior to shipment and are insured against loss or damage in transit. All international customers are responsible for and duties and broker fees. Standard US shipping rates do not include Alaska and Hawaii. Please contact us for a shipping quote to these destinations. If there are any questions, please ask before you make a purchase and/or bid. Return Eligibility You may return most new, unopened items for a refund within 30 days of sale. All returns will be subject to a 20% restocking fee. These items should be in their original packaging and have their serial number or UPC intact. You must return items in new or unused condition with all original materials included with the shipment; thus, the merchandise must be returned in resalable condition: complete in original packaging, unused, and free from damage. All Item(s) must be returned in original condition, undamaged, unopened, unused and uncut complete in original packaging. Returns will not be accepted on items that are:Opened or usedItems cannot be returned once installedMissing their serial number or UPCNon-Returnable ItemsReturned more than 30 days after deliveryReturned without notification Tools and Meters are exchangeable within 3 days of receipt. Non-Returnable Items Policy Some of our products by their very nature are not returnable. The following items are non-returnable and do not qualify for refunds or exchanges:Replacement PartsRefrigerantCompressorsEquipmentElectrical Parts/ComponentsHeating Parts/ComponentsA/C Parts If you have a non-returnable item that arrived damaged or defective please contact us immediately. Restocking Fee All returns are subject to a 20% restocking fee unless other arrangements have been discussed prior to the return being sent in. Return Instructions To return new condition items by mail, send us an email and have your packing slip or order number handy. Once your return is approved, we will provide a return address, and you will receive a Return Merchandise Authorization (RMA) number that you'll write directly on your shipment box. Finally, mail the packing slip along with purchased items, all their contents, and product packaging to the address provided to you. We must receive your returned items within 45 days of the date of sale (see Non-Returnable Items for exceptions). Damage may happen during shipping, and we apologize for the inconvenience this may cause. Please contact customer service if you have received damaged goods, and we will assist you immediately. We inspect all returned items when they arrive at our processing facility. If your return is a result of an error on the part of Climatedoctors, we will refund the full cost of the merchandise and original shipping charges. If you return an item that was opened or shows signs of wear, that item is not eligible for a refund. Products must be received at our returns processing facility before 30 days from the date of sale. You can expect your refund within four weeks from the date you return your package. In most cases you will receive a refund sooner, but we estimate four weeks because of the time required for return shipping (up to 14 days), product inspection at our returns facility (up to 5 business days), and processing from your bank or credit card company (up to 5 business days). All refunds are issued to the original method of payment unless you selected to return for in-store credit. Once your return is processed we will send you an email with your refund details. Error Corrections & Term Amendments Clerical or typographical errors may be found on this site. We reserve the right to correct any errors, inaccuracies, or omissions, and to amend our Return Policy and any information on our website at any time. Climate Doctors is committed to providing you with the best customer service and HVAC/R product knowledge in the industry. Our friendly Team is ready to help answer all your parts questions! Sales or Product Specialists are available: Monday-Friday: 9:00 a.m. to 5:00 p.m. CST. Climatedoctors serves both trade professionals and homeowners with the very best of brand name heating, air-conditioning (HVAC), refrigeration, HVAC equipment, tools and supplies. We can help with everything from large commercial projects to residential heating and air. We're family owned and have continued to build our business on a firm foundation of integrity, commitment and trust. We're big enough to provide a wide selection and competitive prices, but small enough to be flexible and responsive. Our family members (as we call our employees) develop long-term personal relationships with our customers. Some of our clients say that we know their needs almost better than they do, so let us begin to cure all of your comfort needs! 100% New OEM Parts Fast Shipping Click here to see description
Price: 287.04 USD
Location: Colorado Springs, Colorado
End Time: 2024-05-15T14:58:47.000Z
Shipping Cost: N/A USD
Product Images
Item Specifics
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Return policy details:
Brand: Honeywell
Type: Console