Description: Guildline 7620 Wide Band Transconductance Amplifier Comes with a manual and what you see in the pictures. If you don't see it, you probably wont get it. Specifications are from Guildline and may vary slightly due to upgrades, options, or revisions this unit may or may not have. This unit has been tested and is guaranteed to work for 30 days, parts and labor, excluding freight. It is ready to ship! List Price is: $38,500.00 from Guildline (60 Day Delivery Time) The Unit's Serial Number Tag Reads: Serial Number: 60 825 Features: Stability < 10 ppm/hour @ 30 kHz Ranges, (6) 200 µA to 20 A Frequency DC to 1 MHz Compliance 10 volts Guarded output IEEE 488 Interface Over voltage & over current protection Description: Guildline Model 7620 is a very wide band transconductance amplifier. By connecting the output from a stable voltage source to the 7620, it is capable of producing outputs up to 20 amps over a specified frequency range of DC to 100 kHz, and a usable frequency range extending to 1 MHz. The 7620 provides the capability of calibrating any device requiring a known stable source of current up to 20 amps, such as current shunts and current meters. The transconductance amplifier has been designed to satisfy a growing need for AC current measurement of power harmonics in power distribution systems. The output of the 7620 uses a unique patented multi cell array, developed at The National Institute of Standards and Technology (NIST). This output array is extremely stable, with a zero drift of less than 50 ppm/hour at 20 amps at 30 kHz. The 7620 offers an impressive 10 volts output compliance voltage at D.C. and low frequencies, reducing to 5 volts at 100 kHz. A front panel display indicates the compliance voltage existing at the output at all times. Three compliance LEDs indicate the operating output current and frequency band in use. The 7620 is intended to calibrate devices requiring a known stable source of current up to 20 amps. Input errors have been eliminated by providing the unit with a four terminal input. This enables the 7620 to be easily connected to most accurate 4-wire sensing voltage sources. One of the main sources of error in making current measurements is the leakage between the HI and LO terminals of the current source. To alleviate this condition, the 7620 has a driven output guard which provides a buffered signal whose potential follows that of the output HI. The 7620 is fully programmable over the IEEE 488 General Purpose Interface Bus. The Bus address is selectable from the rear panel, and all front panel controls can be duplicated over the Bus with the exception of power on/off. A sophisticated overload detection system is implemented on the unit to control and indicate when the 7620 is operating within its specified limits. It is also possible to operate the unit outside the specification but within its safe limits by disabling part of the protection system. In this case, information is still provided to the front panel and over the Bus as the status of the instrument. Noise and Distortion Specifications: Range: Frequency < or = to 100 Hz: Frequency 100 Hz - 1 kHz: Frequency 1 kHz - 5 kHz: Frequency 5 kHz - 10 kHz: Frequency 10 kHz - 20 kHz: Frequency 20 kHz - 100 kHz: Noise (dB of full scale): Distortion (% rdg.): Noise (dB of full scale): Distortion (% rdg.): Noise (dB of full scale): Distortion (% rdg.): Noise (dB of full scale): Distortion (% rdg.): Noise (dB of full scale): Distortion (% rdg.): Noise (dB of full scale): Distortion (% rdg.): 200 µ A: -50 0.15 -50 0.3 -50 0.3 -25 5.0 2 mA: -60 0.06 -60 0.06 -60 0.06 -60 0.1 -50 0.3 -30 4.0 20 mA: -70 0.03 -70 0.03 -60 0.1 -50 0.3 -40 1.0 -30 2.0 200 mA: -75 0.02 -75 0.02 -75 0.02 -70 0.03 -60 0.1 -50 0.3 2 A: -70 0.03 -70 0.03 -60 0.08 -50 0.3 -40 1.0 -30 3.0 20 A: -60 0.15 -60 0.1 -50 0.2 -50 0.3 -50 0.3 -40 0.7 Gain Stability Specifications: Range: Temp. Coeff. (ppm/°C): Drift: @ 30 kHz (ppm/hr): @ 100 kHz (ppm/hr): 200 µ A: < 10 < 20 2 mA: < 10 < 10 < 100 20 mA: < 15 < 10 < 40 200 mA: < 25 < 10 < 40 2 A: < 30 < 10 < 40 20 A: < 50 < 50 < 50 Phase Input to Output Specifications: Range: Output Delay 5 kHz - 10 kHz (ns): Output Jitter 10 kHz - 20 kHz (ns): 200 µA: 2000 2 mA: 300 1 20 mA: 300 1 200 mA: 300 1 2 A: 300 1 20 A: 500 5 Accuracy (24 Hrs) @ 23°C ±2°C 1 V Input < or = to 5 V Output Compliance Specifications: Range: ±(% of reading + % of range) Frequency DC: Frequency DC - 1 kHz: Frequency 1 kHz - 5 kHz: Frequency 5 kHz - 10 kHz: Frequency 10 kHz - 20 kHz: Frequency 20 kHz - 100 kHz: 200 µA: 0.02 + 0.01 0.15 + 0.02 0.15 + 0.05 10.0 + 0.1 2 mA: 0.015 + 0.01 0.08 + 0.01 0.1 + 0.05 0.2 + 0.1 1.0 + 0.1 10.0 + 0.4 20 mA: 0.01 + 0.01 0.2 + 0.01 0.2 + 0.05 0.15 + 0.1 0.3 + 0.1 1.0 + 0.4 200 mA: 0.01 + 0.01 0.15 + 0.01 0.15 + 0.05 0.15 + 0.1 0.15 + 0.01 1.0 + 0.2 2 A: 0.01 + 0.01 0.15 + 0.01 0.15 + 0.05 0.15 + 0.1 0.15 + 0.01 1.0 + 0.2 20 A: 0.01 + 0.01 0.15 + 0.01 0.15 + 0.1 0.4 + 0.1 1.0 + 0.25 4 + 0.5 Accuracy (1 Year) @ 23°C ±2°C 1 V Input < or = to 5 V Output Compliance Specifications: Range: ±(% of reading + % of range) Frequency DC: Frequency DC - 1 kHz: Frequency 1 kHz - 5 kHz: Frequency 5 kHz - 10 kHz: Frequency 10 kHz - 20 kHz: Frequency 20 kHz - 100 kHz: 200 µA: 0.03 + 0.01 0.15 + 0.02 0.15 + 0.05 10.0 + 0.1 2 mA: 0.025 + 0.01 0.08 + 0.01 0.1 + 0.05 0.2 + 0.1 1.0 + 0.1 10.0 + 0.4 20 mA: 0.02 + 0.01 0.2 + 0.01 0.2 + 0.05 0.15 + 0.1 0.3 + 0.1 1.0 + 0.4 200 mA: 0.02 + 0.01 0.15 + 0.01 0.15 + 0.05 0.15 + 0.1 0.15 + 0.01 1.0 + 0.2 2 A: 0.02 + 0.01 0.15 + 0.01 0.15 + 0.05 0.15 + 0.1 0.15 + 0.01 1.0 + 0.2 20 A: 0.02 + 0.01 0.15 + 0.01 0.15 + 0.1 0.4 + 0.1 1.0 + 0.25 4 + 0.5 Maximum Compliance Specifications: Voltage: 10 V at DC, 5 V RMS at 100 kHz Peak Output Current (DC): 35 A Maximum Continuous Output Current (DC): 20 A Maximum AC RMS Output Current: 20 A at 100 kHz Bandwidth: DC - 100 kHz at 20 A, DC - 300 kHz at 10 A, DC - 1 MHz at 8 A Settling Time: 1s to full specification Input Voltage: 1 V input max. = 1 V RMS, 10 V input max. = 10 V RMS Offset Current: 0.01% of range Input Impedance: 100 kΩ Load Compliance: Resistive & Capacitive Loads to full V-1 compliance, Inductive Loads to 125 µH Short Term DC Stability: ±100 ppm over a 30 minute period, where the absolute value is defined as 2 times the standard deviation of the measurement at full scale, excluding noise, at 10 samples maximum per second. General Specifications: Power Supply: Voltage: 100, 120, 220, 240 VAC ±10% Frequency: 50/60 Hz Consumption: 600 VA Environment: Operating: 18°C to 28°C, < 70% RH non-condensing / 28°C to 40°C, < 50% RH non-condensing Non Operating: -20°C to 60°C, 15 to 80% RH non-condensing Dimensions: 178 mm H x 438 mm W x 457 mm D (7" H x 17.25" W x 18" D) Weight: 20.5 KG (45 lbs) Rack Mounting Version Standard: 19" W For Domestic Customers: Packaging, handling, and order processing included in shipping in all domestic shipments as quoted by the shipping calculator. For International Customers there is a $50.00 minimum for packaging, handling, and order processing. International shipping to be determined by destination. Prior to shipment I will need to know the following information (filled out on a form that I will send you) for International Customers or Packages/Freight being Forwarded internationally. International customers may also be subject to a freight forwarder form if applicable.: (1) Are you the end-user of this item? (2) If you are not the ultimate end-user of the item, please state the ultimate end user's name. (3) What is the ultimate country destination? 05/27/10
Price: 14999.99 USD
Location: Phoenix, Arizona
End Time: 2024-02-29T23:35:44.000Z
Shipping Cost: N/A USD
Product Images
Item Specifics
All returns accepted: ReturnsNotAccepted
Model: 7620
MPN: 7620
Brand: Guildline
Type: Amplifier