Description: Product Basic Information Product Name:Dental X-ray System Working principle:The high voltage generator provides high voltage to both ends of the X-raytube filament and metal target in the internal X-ray source assembly, a large number of electrons aregenerated on the cathode filament of the X-ray tube and move at a high speed in the vacuum tube,impact the metal target to generate the X-ray. The X-ray penetrate the different tissue densities of the body, such as teeth and muscles after pass through the X-ray window and beam tube, the X-ray whichcarry image information through body tissue, are passed through image receiving devices such asphosphor sheets, film or digital image receivers, to show different densities of human tissue images. Application Range: used for the teeth to taking an X-ray photography, with an intraoral imagereceiver, images are obtained for the clinical diagnosis. Structural composition: the product consists of the host (including the X-ray tube, controller andrechargeable battery), beam limiting tube, power adapter, stand and exposure switch. Product DescriptionProduct Description 1.Power Adapter Input Voltage Uniphase AC 100 ~240V,±10% Supply Frequency 50/60Hz,±1Hz Input Power 286W 2.Output Power 25.2W 3.Charge voltage DC 25.2V 4.Charge current 1.0A 5.Nominal value of the focal point 0.8mm 6.Anode angle 19º 7.Available maximum tube voltage at 2mA 60kV 8.Maximum output electric power 0.12kW 9.Maximum loading factor combination 60kV 、2mA 、2s 10.Repeatability of radiation output No more than 0.5 11.Tube voltage (The deviation is within the range of ±10%) 60kV 12.Tube current (The deviation is within the range of ±20%) 2mA 13.Running mode Discontinuous operation, maximumexcitation (open) time : minimumexcitation (close) time = 1:30 14.Total filtration of X-ray tube assembly >2.5mm Al 15.Intrinsic filtration of X-ray tube assembly 0.75mm Al 16.Additional filtration 1.00mm Al 17.Half-value layer ≥1.5mm Al(60kV) 18.Leakage radiation ≤0.25mGy/h(60kV 、2mA 、2s) 19.Adjustment range of the loading time 0.01 ~2.00s,adjustable 20.Distance of the Focal point to skin (The deviation is within 0~5%) 211mm±3mm21.X-ray field size at the end of beam limiting tube round ,Φ 56mm±3mm22.Nominal electric power 0.12kW(60kV 、2mA 、0.1s)23.Available maximum tube current at 60kV 2mA 24.Inverter frequency of the high voltage generator 70kHzNote: the loading time adjustment range meets the R10 series for the adjustment. Product basic safety features(1) Safety category:Class Ⅱ or internal power supply class ,does not work while charging.(2) Classified by electric shock protection type:Type B application section.(3) Classified by the degree of protection against fluid intake:Common equipment.(4) Classified by the manufacturer's recommended disinfection and sterilization methods:As required by the manufacturer to carry out.(5) Classified by the degree of safety for use with flammable anesthetic gases mixed with air or with oxygen or nitrous oxide:NonAP/APG type.(6) Classified by operation mode:Discontinuous operation,Maximum excitation (open) time: Minimum excitation (close) time =1:30.(7) The product has no application part with protection against defibrillation discharge effect.(8) Whether the equipment has a signal output or input part:No.(9) The product is a common equipment.(10) Permanent or non-permanent installation equipment:Non-permanent installation equipment.(11) Radiation type:Ionizing radiation.(12) Radiation property:X ray.(13) Radiation distribution:The X-ray radiates from the positive direction of 6cm circle in the window of the limited beam barrel when used. X-ray tube technical specification 1.The X-ray tube model XD10D-0.5 / 70 2.Nominal value of the focal point 0.8mm 3.Target material Tungsten 4.Maximum working tube voltage 70kV 5.Anode angle of the X-ray tube 19º 6.Intrinsic filtration 0.75 mm Al 7.Filament current 2.0 A 8.Filament voltage 2.85 ± 0.5 V FDA Statement:The sale of this item may be subject to regulation by the U.S. Foodand Drug Administration and state and local regulatory agencies.So you can bid it on this item only if you are an authorized purchaser.If the item is subject to FDA regulation,We have to verify your statusas an authorized purchaser of this item before shipping of the item.Thanks for your understanding!
Price: 654.55 USD
Location: Zhengzhou, Henan
End Time: 2025-01-05T05:32:33.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: ETERFANT
MPN: GJ103020001
Modified Item: No
Intended Use/Discipline: Dental Laboratory, Dentistry
Country/Region of Manufacture: China
Product Name: Dental X-ray System
Output Power: 25.2W
Charge voltage: DC 25.2V
Charge current: 1.0A
Nominal value of the focal point: 0.8mm
Anode angle: 19º
Available maximum tube voltage at: 2mA 60kV
Maximum output electric power: 0.12kW
Maximum loading factor combination: 60kV 、2mA 、2s
The X-ray tube model: XD10D-0.5 / 70
Maximum working tube voltage: 70kV
Anode angle of the X-ray tube: 19º
Intrinsic filtration: 0.75 mm Al
Filament current: 2.0 A
Filament voltage: 2.85 ± 0.5 V