Description: ETC-098 Digital Ultrasonic thickness gauge meter used metallurgy shipbuilding aviation 0.75-300.0mm Ultrasonic thickness tester Details1. FeaturesThe instrument is based on the principle of ultrasonic measurement.It can measure thickness of material which allows the ultrasonic wave penetrating with constant speed and reflecting from the back side.With used in many areas of industry,ETC-098 has precise measurement,eg petroleum,metallurgy,shipbuilding,aviation,spacefight and so on.It can measure on various type of raw material and component parts.Applicable to monitor pipe and pressure ressel. 2. Basic deliveryMain unit 1pc5MHz probe 1pcCouplant 1pc 3. Technical specificationsRang: 0.75-300.0mm(determined by probe)Accuracy: ±(1%H+0.1)mmLower limit of pipe (steel):φ20mm×3.0mm(5MHz) φ15mm×2.0mm(10MHz)sound velocity rang: 1000m/s-9999m/sTo measure velocity by thickness: Rang:1000m/s-9999m/sThickness of the measured sample: ≥20mm(Accuracy: ±5%)Temperature: 0℃-40℃Power supply: DC1.5V×2Dimensions: 150mm×73mm×32mmWeight: 400g 4. Button instructionPOWER:Power switch.The instrument can manual turn on, turn off automatically and manually.(Waiting for measurement over 1 minute,it will automatic power off)LIMIT: Set upper and lower limit for warningCHM:choose frequency of probeCHV:choose velocity>>: Move cursor to enter data.∧:data plus 1/ data query∨:data minus 1/ data query /zero the memory1 :to confirm/change speed velocity2 :backlight switch 5. Display instruction5M:display the frequency of probe(including 2M,5M,10M and high frequency H2M)NO:85 display the number of record memoried(the number up to 85)1. lower power2. sign of well coupledCH:3 5900m/s: display the channel and velocity of sound,the instrument has 8 channels to set.0.0mm: the current data of measurement 6.Measure and operate1. Just put the plug in the socket of main unit and press the “POWER’’key to switch on, there is displaying the last frequency of prob and velocity of sound.2. If it is necessary,please choose proper prob and velocity of sound,“CHM”key will help to change the frequency(2M,5M,10M,H2M is avaliable).While “CHV”key is for changing and choosing the velocity of sound. during the unit is waiting for measurement ,press the key,then the unit step into the velocity of sound changing status,velocity can be changed by three buttons(“》”move cursor, “∧”plus 1,“∨”minus 1).3. Drop the couplant on the sample to be measuresed, couple the probe with the sample.The thickness is display on the screen.If taking the probe away the value wil be keep on ,but the sign of coupling will disappear.Meanwhile, the number of record memoried plus 1(the eighty-fifth record should be changed if records exceeds 85) 7.Setting upper and lower limitThe instrument have the upper and lower limit setting function,and if the measurement is above the upper limit or under the lower limit during the operation,there is buzz sound to report.Press “LIMIT”key,the instrument step into the upper and lower limit setting status.Meanwhile “LIMIT: L”is displaying,which indicate inputting the lower limit.Cooperating with “>>”“∨”“∧” to input the lower limit,then press to confirm.After this ,the “LIMIT :H”is displaying,the setting is as same as the lower limit.Thus the warning setting is over. 8.Measure the velocity of soundIf it is necessary to measure the velocity of sound,firstly,measure the standard thickness of sample by vernier caliper,the mininum thickness suggested is 20 mm.When the unit enter state of readiness,press “>>” to enter state of measurement ,the set operation is as follows:Input the measured thickness (setting method has referenced in the 6th part),and press to confirm. Couple the probe with the sample, put away the probe after the signal of coupling appears, the screen appers the velocity of sound,meanwhile the current velovity of channel has been replaced by the measurement. 9.Two point calibration In order to improve accuracy ,the instrument provides two point calibration function, you can choose to use it as needed,when the instrument is turn off,firstly press ,next press “POWER”, then release "POWER" key before the "ZERO" key, the instruement step into the two point calibration state.Display: “INPUT:L”:It prompts to input the thickness of the first point,cooperate“>>”,“∨”with“∧”to input the value,then press to confirm.Display: “INPUT:H”:It prompts to input the thickness of the second point,cooperating “>>”,“∨”with“∧”to input the value,then press to confirm.Display: “CALXXX”:It prompts to sample the first point, couple the probe with the first sample,don’t take away the probe untile the sign of probe displayed.Display: “CALXXX”:It prompt to sample the second point, couple the probe with the second sample,don’t take away the probe untile the sign of probe displayed,after few seconds the instruement finished calibration and turn into the state of readiness.10.Save and check thicknessThe instrument provides saving and checking thickness.It can save 85 value.when measurement is finished ,the thickness saved one by one,the screen displays the number of record memoried.When it over 85 values ,the current result will cover the 85th record. In the state of readiness, use “∧”and“∨”to roll from top to bottom ,then the screen displays the serial number of record and the thickness value at the same time.When the serial number is 85 , press “∧”to display the sign of “NO : 0 ? ”which prompts that whether to zero the memory or not,press to zero,press any other keys to cancel. 11.Display the conversion of unit The instrument supplies two kinds of unit.When the instrument is in the turn off state ,firstly press “LIMIT” , then press the “POWER”key, and release "LIMIT" key before the " POWER " key, the conversion of "mm or in" finished. the result will saved until the next conversion. 12. AttentionThe instrument provide 5mm steel board.Using the other samples to measure,you need to drop couplant . Clean sample after used to keep prob from rusting.*Alcoho,dilution and so on would corrod the case of instrument,especially the window.During cleaned,you just need to wipe it with a little water.the surface of probe is made of propylene resin ,it is sensitive to the rough surface ,so press it softly .when measured at the ordinary temperature ,the temperature of surface to be measured should not be over 60ºC , unless the probe wil be injured . take care of instrument to avoid damp environment and collision.If the instrument is not used for a long time,you should take out the battery.Unless it may flow the liquid which cause damage to the instrument. INTERNATIONAL SHIPPING:The package will be shipped by DHL, FEDEX or EMS. After we shipped the parcel,we'll fill in the tracking number.Please write the correct address and telephone number when you make orders,so the courier can contact you when they deliver the parcel to you. thanks CUSTOMS CLEARANCE1.We always make lower amount on invoice, if you need one different, please leave us a message.2.The buyer is responsible for any tax and/or duty charged by their country. PAYMENT INFORMATION:1.We can accept Paypal,T/T,Credit Cards and so on. WARRANTY INFORMATION:1.All the products have been checked and packed in good condition before dispatch.2.All the products with one year warranty.3.If you find any quality problems,please send it back within 3 days,and we'll send you a new one or refund you the payment after we get the returned one.4.Buyers have to pay for the return cost and we will pay the cost for resend5.All products returned should be in new conditions. FEEDBACK:1.A good feedback is very important for our store,if you feel satisfied with our products,please give us positive feedback.2.Please contact us before leaving any negative or neutral feedback,We will work with you to solve any problems.
Price: 228 USD
Location: Shenzhen, Guangdong
End Time: 2024-10-30T07:56:17.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Dimensions: 150mmx73mmx32mm
MPN: ETC-098
Power supply: DC1.5Vx2
Model Number: ETC-098
Rang: 0.75-300.0mm
Weight: 400g
Brand: AERMANDA
Type: Ultrasonic thickness gauge
Accuracy: ±(1%H+0.1)mm
Unit Type: Unit
sound velocity rang: 1000m/s-9999m/s
Country/Region of Manufacture: China
Unit Quantity: 1