London Jeans

English/Spanish 3 Phase Transformer Ratio Tester Turns Ratio Group Meter TTR

Description: Product Overview:For the power system, transformers are the core equipment in the system, so the long-term and reliable operation of transformers will be related to the stability and reliability of the entire system. Before the newly installed transformer is put into operation and in accordance with the preventive testing regulations of State Grid, it is required to conduct regular turns ratio or voltage ratio tests on the operating transformer. The traditional variable ratio bridge operation is cumbersome, the reading is not intuitive, and necessary conversions need to be made. The test result is only the value of one phase change ratio. This transformer ratio tester overcomes the shortcomings of traditional ratio bridge testing. The screen adopts a large high-resolution LCD display screen, which is convenient for on-site use. It has a Chinese menu prompt function, easy and intuitive operation, and can complete three-phase ratio testing in one go. The testing speed is fast and the accuracy is high. Product Features: ​ 1. The three-phase CNC sine inverter power supply output has soft start and soft stop functions, so the testing speed is fast and the accuracy is high.2. Three phase transformer, single-phase transformer, PT, CT, Z-type transformer ratio, group, polarity testing function.3. CT ratio polarity testing function.4. It has angle difference testing function during single-phase testing.5. The tap changer can be tested up to 99 gears.6. Wide testing range, up to 10000.7. High and low voltage reverse connection reminder.8. Output short circuit reminder.9. Non power-off clock and date display; The data storage method is local storage, with 100 test data pieces. The stored data can be transferred to a computer (PC);10.Thermal printer printing function.11. Small size, light weight, convenient for carrying and use.​Technical parameters: ​ ​Range0.8~10000Accuracy± (reading × 0.1%+2 words) (less than or equal to 1000)± (reading × 0.2%+2 words) (greater than 1000 but less than or equal to 3000)± (reading × 0.3%+2 words) (greater than 3000)Resolution Ratio0.9~9.9999(0.0001)10~99.999(0.001)100~999.99(0.01)1000~9999.9(0.1)10000(1)Workingpower supplyAC100-240V, 50/60Hz (battery charging voltage)Host weight4.5KgVolume320mm(L)×280mm(W)×135mm(H)Operating temperature-10℃~50℃Relative Humidity<90%, no condensation

Price: 927.19 USD

Location: 武汉市

End Time: 2025-01-10T08:58:35.000Z

Shipping Cost: 0 USD

Product Images

English/Spanish 3 Phase Transformer Ratio Tester Turns Ratio Group Meter TTREnglish/Spanish 3 Phase Transformer Ratio Tester Turns Ratio Group Meter TTREnglish/Spanish 3 Phase Transformer Ratio Tester Turns Ratio Group Meter TTREnglish/Spanish 3 Phase Transformer Ratio Tester Turns Ratio Group Meter TTREnglish/Spanish 3 Phase Transformer Ratio Tester Turns Ratio Group Meter TTREnglish/Spanish 3 Phase Transformer Ratio Tester Turns Ratio Group Meter TTREnglish/Spanish 3 Phase Transformer Ratio Tester Turns Ratio Group Meter TTREnglish/Spanish 3 Phase Transformer Ratio Tester Turns Ratio Group Meter TTR

Item Specifics

Return shipping will be paid by: Buyer

All returns accepted: Returns Accepted

Item must be returned within: 30 Days

Refund will be given as: Money Back

Return policy details:

Power Frequency: 50/60Hz

Product Name: Transformer Turns Ratio Test Meter

MPN: JH2702N

Output Voltages: No less than 50V

Feature: Charge with Electricity, no battery-in

Brand: JHJC

Resolution Ratio: 0.9-10000

Function: PT, CT, Z-type transformer ratio, group, polarity testing functio

Type: Voltmeter Ammeter

Unit Type: Unit

Language: English/Spanish to choose

Country/Region of Manufacture: China

Unit Quantity: 1

Working power supply: AC100-240V

Recommended

Rear KYB Excel-G Strut Assembly fits Acura TSX 2012-2014 Wagon 78JHJC
Rear KYB Excel-G Strut Assembly fits Acura TSX 2012-2014 Wagon 78JHJC

$127.91

View Details
Engine Cooling Fan Motor Connector fits Ford Taurus 1986-1990 16JHJC
Engine Cooling Fan Motor Connector fits Ford Taurus 1986-1990 16JHJC

$28.09

View Details
For 2002-2010 Dodge Ram 2500 Drive Belt Tensioner Pulley Dorman 71134JHJC 2006
For 2002-2010 Dodge Ram 2500 Drive Belt Tensioner Pulley Dorman 71134JHJC 2006

$47.07

View Details
Thermostat O-Ring Gates 62JHJC83 for Ford Pinto 1972 1973 1971 1974
Thermostat O-Ring Gates 62JHJC83 for Ford Pinto 1972 1973 1971 1974

$17.77

View Details
For 2003-2008 Pontiac Vibe Water Temperature Sensor 67786JHJC 2004 2005 2006
For 2003-2008 Pontiac Vibe Water Temperature Sensor 67786JHJC 2004 2005 2006

$20.49

View Details
For 1984-2001 Jeep Cherokee Shock Absorber Rear Fox Shox 17439JHJC 1985 1986
For 1984-2001 Jeep Cherokee Shock Absorber Rear Fox Shox 17439JHJC 1985 1986

$349.95

View Details
For 1992-1995 Mitsubishi Expo Steering Rack Boot Kit Front 97945JHJC 1993 1994
For 1992-1995 Mitsubishi Expo Steering Rack Boot Kit Front 97945JHJC 1993 1994

$22.27

View Details
Carter Fuel Pump fits Dodge Grand Caravan 1996-2000 85JHJC
Carter Fuel Pump fits Dodge Grand Caravan 1996-2000 85JHJC

$96.91

View Details
Action Crash Washer Reservoir fits Nissan Rogue Select 2014-2015 39JHJC
Action Crash Washer Reservoir fits Nissan Rogue Select 2014-2015 39JHJC

$59.94

View Details
For 2006-2008 Ford F150 Fuel Pump Delphi 73252JHJC 2007 5.4L V8 FLEX
For 2006-2008 Ford F150 Fuel Pump Delphi 73252JHJC 2007 5.4L V8 FLEX

$197.95

View Details