Description: Criticare VitalCare 506N3 Series Patient Monitor Up for sale is a VitalCare 506N3 Series Patient Monitor manufactured by Criticare. Item is in used condition has been tested and does power on. Item has minor scuff marks from transport and being in storage. Includes all and only what is pictured. Power cord included. Overview Spot-check or continuously monitor three critical parameters with a single monitor. Designed to travel everywhere you do, the VitalCareTM 506N3 Series with integrated carrying handle attaches quickly and easily to roll stands. Available in multiple configurations, the VitalCare provides maximum versatility and cost-effectiveness. Smart battery management allows up to 100 non-invasive blood pressure measurements on a single battery charge. With a compact design that is easily set up for spot-checks or continuous monitoring, the monitor adapts readily to hospital, clinic and transport requirements. Features ComfortCuff® NIBP measures on-inflation for faster, more comfortable readings.Choice of CSI’s DOX® or Nellcor OxiMax® pulse oximetry.Audible and visual alarms are adjustable for use in continuous monitoring.Large responsive keys for fast spot-checks with easy to clean membrane keypad.Accomodates all patient types from adult to neonate.Multi-patient trend memory.Rechargeable battery with direct AC power.Specifications NIBP (NON-INVASIVE BLOOD PRESSURE) Technique: Oscillometric measure upon inflation Measurement Cycle: < 40 sec. typical STAT Mode: 5 min. of continuous measurements Automatic Measurement: 1, 2, 3, 5, 10, 15, 30, 45, 60 min.; 2, 4 hrs; STAT Inflation Pressure Range: Adult: 30 to 300 mmHg; Pediatric: 30 to 150 mmHg; Neonate: 20 to 150 mmHg Resolution: 1 mmHg ransducer Accuracy: ±2 mmHg or ±2% of reading, whichever is greater over full range Clinical Accuracy: Complies with AMI SP-10:2002 PULSE OXIMETRY Range: 1% to 99% Resolution: 1% Accuracy (DOX only): 70% to 99% range: ±2%; 50% to 69% range: ±3%; < 49%: unspecified Accuracy (OxiMax only): 70% to 99% range: ±2% < 69%: unspecified Method: Dual wavelength LED Audio: Tone with each detected pulse; pitch varies with saturation HEART RATE (PULSE) Range: 20 to 300 bpm Accuracy (DOX Only): ±1 bpm or ±1% of reading, whichever is greater; unspecified for 240 bpm Accuracy (OxiMax Only): ±2 bpm or ±1% of reading, whichever is greater; unspecified for 240 bpm Update Time: 1 sec. Resolution: 1 bpm Pulse Volume: 10 levels or Off TEMPERATURE (TURBOTEMP) Type: TurboTemp Method: Predictive or continuous Channels: 1 Predictive Mode Range: 96 to 106 degrees F (35.6 to 41.1 degrees C) Continuous Mode Range: 80 to 106 degrees F (26.7 to 41.1 degrees C) Accuracy: ±0.2 degrees F (±0.1 degrees C; measured in calibrated water bath while in continuous mode Resolution: ±0.1 degrees F or ±0.1 degrees C Response Time: 10 seconds typical (oral) TEMPERATURE (FILAC) Method: Predictive of Continuous Channels: 1 Range: 86° to 109.4F (30° to 43°C Accuracy (Continuous): ±0.2°F (±0.1°C) Accuracy: (Predictive): ±0.2°F (±0.1°C) (Compliant with EN 12470-3 and ASTM E1112:98) Resolution: ±0.1°F (±0.1°C) Predictive Response Time: 10 sec. typical 800x600 Normal 0 false false false EN-PH X-NONE X-NONE MicrosoftInternetExplorer4 MEDICAL DISCLAIMER "The sale of this item may be subject to regulation by the U.S. food and drug administration and state and local regulatory agencies. If so, you must be an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item. Regardless of the origin of this equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or coincidental, associated in any way with the equipment. The purchaser, by bidding or buying this equipment, indicates their knowledge of, and agreement to the terms of this disclaimer." 5-2-5
Price: 500 USD
Location: Macon, Georgia
End Time: 2024-03-04T23:29:26.000Z
Shipping Cost: N/A USD
Product Images
Item Specifics
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money back or replacement (buyer's choice)
Brand: Criticare
MPN: 506N3
Type: Patient Monitor
Intended Use/Discipline: Emergency Medicine, Family Medicine, General Surgery
Model: VitalCare 506N3 Series
Country/Region of Manufacture: United States
Display Type: LED
Display Parameters: SpO2, pulse rate, NIBP, temperature, pulse bar
Display Text: Alphanumeric LCD
COM Port: Serial, RS232 compatible
Weight: Base unit with battery: 6.95 lbs (3.1 kg)
Size: 8.7 in (H) x 7.1 in (W) x 6.5 in (D)
Voltage: 100 to 240 VAC; 50/60 Hz
Operating Temperature: 32° to 113°F (0° to 45°C)
Storage Temperature: 23° to 122°F (-5° to 50°C)
Operating Humidity: 15% to 90%, noncondensing