Description: Product Name : 2 PCS 2 in 1 15ch RS485 RS232 Modbus RTU Relay PLC DO Board Serial Port Switch Controller with TVS ESD Protection Package included: 2 PCS DC 12V/24V N438C15 15 Channel RS485 /RS232 Modbus Rtu Relay Board Feature: Operating voltage: DC 12V (12V version); 24V (24V version) Operating current: Standby 14MA, 1 relay guide 44MA, 2 relays 69MA, 3 relays 95MA, 4 relays 121MA, 5 relays 149MA, 6 relays 175MA, 7 relays 199MA, 8 relays 226MA, etc open close Momentary Self-locking Interlock Delay 6 Commands MODBUS command supports 03 06 16 function code Maximum delay of 255 seconds under the MODBUS command MODBUS commands can also be input by Modbus Poll in addition to the serial port super terminal input. In MODBUS command mode, up to 64 devices can be used in parallel The default baud rate is 9600BPS, the baud rate can be selected by command 2400 4800 19200 38400 57600 115200BPS The check method can be selected as no check, even check and odd check The data sending return time can be set, the maximum can be set to 1000ms Dimensions 173*96*20mm (circuit board) 179*108*48mm (with rail box): Weight: 250.5g (circuit board); 415g (with rail box) Maximum load:10A/250VAC ,10A/125VAC,10A /30VDC, 10A /28VDC ,10A /12VDC Function Description: NO : Relay normally open contact COM : relay common contact NC : Relay normally closed contact Open :The NO connects to the COM, and the NC disconnects the COM Close :The NO disconnects the COM, and the NC connects to the COM Crawl :Enter the tap command, with the relay on and off after 600 ms Auto-lock :Enter the self-lock command, the relay on, enter the self-lock command again, the relay off, and so on delay :Input the delay command, the relay turns on, after waiting for the set time, the relay turns off; during the delay period, after the turn-off command is input, the relay turns off immediately Slave address:A0-A5 are slave addresses, and 64 different slave addresses can be selected. In the MODBUS command mode, the slave address of the MODBUS command must be the same as the dial code of A0-A5 to communicate. Refer to the N438C15 15-channel Modbus rtu Command Typical application 1.Control an individual module 2.MODBUS command mode (HEX), there are various control methods: serial port hyperterminal control (need to manually add CRC check code), Modbus Poll software control (software automatically adds CRC check code), PLC or microcontroller program control Wiring diagram 1 Power supply DC12V/24V, load DC 12V/24V circuit, wiring as shown below. Load LOAD can be LED lights, fans, motors, cameras and other DC 12 V/24V devices 2 Power supply DC 12V/24V, load DC 1-100V or AC 85-265V, wiring as shown below. The load LOAD can be DC 1-100V or AC 85-265V equipment such as LED lights, fans, electric lamps, fluorescent lamps, solar water heaters, etc.
Price: 86.73 USD
Location: Guangzhou
End Time: 2024-09-02T06:00:12.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: eletechsup
Type: DC 12V/24V
MPN: N438C15*2
Available Variations
Color: 12V Version
Price: 86.73 USD
Available Quantity: 200
Quantity Sold: 0
Color: 24V Version
Price: 86.73 USD
Available Quantity: 200
Quantity Sold: 0